Structural design is not only about creating a model and running calculations. Every project must also be checked against the right design standards for its location, material, loading conditions and regulatory requirements.
Advance Design helps structural engineers connect FEM analysis, load generation, code-based design checks, optimization and reporting in one workflow. Within that workflow, national codes and design standards control how load combinations are generated, how climatic and seismic actions are defined, and how reinforced concrete, steel, timber, masonry and composite elements are verified.
This page explains which standards are available in Advance Design, how to understand the difference between Eurocodes, National Annexes and national codes, and how to choose the right standard for your project.
National codes are structural design rules used to verify whether a building or civil engineering structure satisfies the required safety, serviceability and durability criteria. They define how loads are combined, how environmental actions such as wind and snow are calculated, how seismic forces are considered, and how structural members are checked for each material.
In Advance Design, these standards are configured at project level through the Localization Configuration settings. Depending on the selected localization, the software applies the relevant standards for combinations, seismic actions, climatic actions, reinforced concrete, steelwork, timber, masonry and other design workflows.

This matters because the selected standard can affect:
Many European projects are designed using the Eurocodes. However, the Eurocodes are often used together with a National Annex, which adapts certain parameters for a specific country.
Other regions use independent national standards. For example, the United States commonly uses ASCE for actions, ACI for concrete and AISC for steel, while Canada uses National Building Code / Canadian standards and CSA material design standards.
| Type of standard | What it means | Examples in Advance Design |
| Eurocode with National Annex | A Eurocode framework adapted with country-specific parameters | EC0, EC1, EC2, EC3, EC5, EC6, EC8 with National Annexes for selected countries |
| Independent national code | A separate national code family, not a Eurocode annex | ASCE 7, ACI 318, ANSI/AISC 360, CSA S16, CSA A23.3, CSA O86, NBC |
| Local or legacy national rule | A country-specific standard used for selected workflows or existing design practice | BAEL91, CM66, NV65/NV2009, PS92, P100, RPS 2011, RPA99-2003, CR0/CR1/CR6 |
| Material or profile standard | A library or specification used for materials and cross-sections | EN 10025, EN 10210, EN 10219, AISC, CISC, European profiles, North American profiles |
The right standard depends first on the project location and the design requirement. A roof wind load problem, for example, is not a concrete design problem. It belongs to climatic actions, so the relevant family is EC1 / EN 1991-1-4 or the applicable national wind standard.
| Project requirement | Standard family to check | Typical use in Advance Design |
| Load combinations | EC0, ASCE, Canadian code family, NTC, BAEL, CM66, CR0 | ULS/SLS combinations and concomitance rules |
| Wind and snow loads | EC1, ASCE 7, Canadian code family, NTC, NV65/NV2009, CR1 | Automatic wind and snow generation, roof pressure zones, snow accumulation |
| Seismic analysis | EC8, NBC, ASCE/IBC, NTC, PS92, P100, RPS, RPA | Seismic load case families, response spectrum settings, modal spectral analysis |
| Reinforced concrete design | EC2, ACI 318, CSA A23.3, NTC, BAEL | RC beams, columns, walls, slabs and footings |
| Steel design | EC3, ANSI/AISC 360, CSA S16, NTC, CM66 | Steel member checks, stability, optimisation and shape sheets |
| Composite steel-concrete design | EC4, AISC 360-16 | Composite beams and floor decks |
| Timber design | EC5, CSA O86, NDS, NTC | Timber member verification, deflection, buckling, fire and optimisation |
| Masonry design | EC6, NTC 2018, CR6-2013 | Masonry wall verification |
| Material selection | EN, ACI, CSA, NTC and other material references | Material libraries for steel, concrete, timber and masonry |
| Cross-section selection | AISC, CISC, European and North American profiles | Profile libraries and structural section data |
If you are checking wind actions on a roof, the relevant standard is a climatic action standard, not a material design standard.
For Eurocode projects, wind actions are covered by Eurocode 1, particularly EN 1991-1-4, with the applicable National Annex. In Advance Design, this belongs to the climatic actions workflow, where wind and snow load families are generated according to the selected standard.
For a UK project, for example, you would select the Eurocode 1 climatic standard with the United Kingdom National Annex where required by the project specification. For a US project, the corresponding workflow would use ASCE 7 wind provisions. For a Canadian project, the corresponding Canadian climatic standard should be selected.
The same principle applies to snow. Snow is a climatic action, so it should be configured through the climatic load family, not through concrete, steel or timber design settings.
Advance Design standards are selected in the Localization Configuration dialog. This is where users define the interface and report language, localization settings, and the design standards that will be used for new projects.
In practice, use this workflow:
The lists below organize the available standards by engineering workflow. This makes it easier to identify the standard required for a specific task, such as generating wind loads, creating load combinations, checking steel members or designing masonry walls.
Load combination standards define how actions are combined for ultimate limit states, serviceability limit states and other design situations.
Use this section when the project requirement is about how actions should be combined, not how an individual material should be designed.
| Standard | Region / country |
| EC0 with National Annexes | France, Great Britain, Germany, Portugal, Romania, Poland, Spain, Slovakia, Czech Republic |
| CBN 2010 | Canada |
| CBN 2015 | Canada |
| ASCE 7-10 | USA |
| ASCE 7-16 | USA |
| NTC 2008 | Italy |
| NTC 2018 | Italy |
| BAEL 91 | France |
| CM66 | France |
| CR0-2012 | Romania |
Climatic standards control wind and snow load case families. These are the standards to use when calculating wind pressure on facades and roofs, snow loads, roof-specific climatic effects and related load generation.
Use this section for:
| Standard | Region / country |
| EC1 with National Annexes | France, Great Britain, Germany, Portugal, Romania, Poland, Spain, Slovakia, Czech Republic |
| CBN 2010 | Canada |
| CBN 2015 | Canada |
| ASCE 7-10 | USA |
| ASCE 7-16 | USA |
| ASCE 7-22 | USA |
| NTC 2008 | Italy |
| NTC 2018 | Italy |
| NV65-84/2009 / NV2009 | France |
| CR1-1-3/CR1-1-4 (2012) | Romania |
Concrete design standards are used for reinforced concrete elements and design modules such as beams, columns, walls, slabs and footings.
Use this section when checking concrete members or generating reinforcement calculations and RC design documentation.
| Standard | Region / country |
| EC2 with National Annexes | France, Great Britain, Germany, Portugal, Romania, Poland, Spain, Slovakia, Czech Republic |
| CAN/CSA A23.3-14 | Canada |
| ACI 318-14 | USA |
| NTC 2008 | Italy |
| NTC 2018 | Italy |
| BAEL91 | France |
Steel design standards are used for steel member verification, stability checks, cross-section classification, member optimisation and steel design reports.
Use this section for steel-framed buildings, steel members, stability verifications, steel optimisation, cold-formed member workflows and steel design result interpretation.
| Standard | Region / country |
| EC3 with National Annexes | France, Great Britain, Germany, Portugal, Romania, Poland, Spain, Slovakia, Czech Republic |
| CAN/CSA S16-09 | Canada |
| CAN/CSA S16-14 | Canada |
| CAN/CSA S16-19 | Canada |
| ANSI/AISC 360-10 (ASD & LRFD) | USA |
| ANSI/AISC 360-16 (ASD & LRFD) | USA |
| NTC 2008 | Italy |
| NTC 2018 | Italy |
| CM66 | France |
Composite design applies to structural elements where steel and concrete act together, such as composite beams and floor decks. In Advance Design, composite linear elements are steel-based I-shaped beams classified as composite beams, and the composite standard must remain synchronized with the steel standard.
Use this section for composite beams, composite floor decks, shear connector design, effective width settings, construction-stage checks and final-stage composite verification.
| Standard | Region / country |
| EC4 – General | General Eurocode workflow |
| EC4 – France | France |
| EC4 – United Kingdom | United Kingdom |
| EC4 – Romania | Romania |
| EC4 – Germany | Germany |
| EC4 – Czech Republic | Czech Republic |
| EC4 – Poland | Poland |
| EC4 – Slovakia | Slovakia |
| EC4 – Spain | Spain |
| EC4 – Portugal | Portugal |
| AISC 360-16 | USA |
Timber design standards are used for timber member verification, deflection checks, resistance checks, buckling, lateral-torsional buckling, fire resistance and timber shape optimisation.
Use this section for timber beams, columns and other timber linear elements where member resistance, stability, deflection or fire checks are required.
| Standard | Region / country |
| EC5 with National Annexes | France, Great Britain, Germany, Portugal, Romania, Poland, Spain, Slovakia, Czech Republic |
| CSA O86-19 | Canada |
| NDS 2018 (ASD and LRFD) | USA |
| NTC 2008 | Italy |
| NTC 2018 | Italy |
Masonry standards are used in the Masonry Wall module, where masonry walls are modelled as vertical planar shell elements and verified according to the selected masonry design standard.
Use this section for masonry wall verification, including walls with or without openings, masonry unit and mortar definition, and detailed or simplified masonry calculation workflows.
| Standard | Region / country |
| EC6 with National Annexes | France, Great Britain, Germany, Romania, Poland, Spain, Portugal, Slovakia, Czech Republic |
| NTC 2018 | Italy |
| CR6-2013 | Romania |
Seismic standards control the seismic load case families, spectrum settings and related modal spectral analysis parameters.
Use this section for seismic load generation, response spectrum analysis, modal spectral analysis, damping correction, accidental torsion and seismic load combinations.
| Standard | Region / country |
| EC8 with National Annexes | France, Romania, Germany, Portugal, Spain, Slovakia, Czech Republic |
| NBC 2010 | Canada |
| NBC 2015 | Canada |
| NBC 2020 | Canada |
| ASCE 7-10 / IBC 2012 | USA |
| ASCE 7-16 / IBC 2018 | USA |
| IBC 2012 | USA |
| NTC 2008 | Italy |
| NTC 2018 | Italy |
| PS92 | France |
| PS92-2010 | France |
| P100/2006 | Romania |
| P100-1/2013 | Romania |
| RPS 2011 | Morocco |
| RPA99-2003 | Algeria |
Material standards and libraries help define the properties used for structural elements. Advance Design includes material references for steel, concrete, timber and masonry.
| Material type | Supported references |
| Steel | AISC ASTM, CAN/CSA CISC G40, EN 10025 2-6, EN 10210-1, EN 10219-1, BS EN 1993-1-1, NF EN 10025 2-6 for buildings, NF EN 10025 2-6 for other structures |
| Concrete | ACI 318 & 318M, CAN/CSA A23, EN 206, NFB18-406, STAS 10107/0-90, NTC |
| Timber | EN 14080-1 for glued timber, EN 14374/14279 for veneer plywood, EN 338/2016 for softwoods and hardwoods, NP 005, CSA O86-19 for glue-laminated timber, SCL and sawn lumber, NDS 2018 for glue-laminated timber and sawn lumber |
| Masonry | EN 1996 |
Cross-section libraries provide the profile data used for structural members. Advance Design includes standard and regional profile libraries, and users can also define, import and export custom cross-sections.
Supported cross-section libraries include:
Advance Design also includes a Cross Sections module for defining custom sections, calculating section properties and exporting calculated sections to the Advance Design user sections library.
This section helps users search by project location. Always confirm the required code with the client, local authority and project specification before selecting the project standard.
For many European projects, Advance Design supports Eurocodes with National Annexes. Depending on the design task, these include:
National Annex coverage varies by workflow, but the available standards include support for countries such as France, Great Britain / United Kingdom, Germany, Portugal, Romania, Poland, Spain, Slovakia and Czech Republic.
French workflows in Advance Design include Eurocode National Annexes and selected French standards, including BAEL91 for concrete, CM66 for steel and combinations, NV65/NV2009 for climatic actions, and PS92 / PS92-2010 for seismic analysis. Use these standards when working on French projects that require French National Annexes or legacy French design rules.
Advance Design includes Eurocode National Annex support for United Kingdom across several workflows, including load combinations, climatic actions, concrete, steel, timber and composite design. Use these standards when a UK project requires Eurocode-based design with the UK National Annex.
Advance Design includes German National Annex support for Eurocode-based workflows, including load combinations, wind and snow actions, concrete, steel, timber, composite and seismic analysis. Use these standards when the project specification requires German National Annex parameters.
Romanian workflows in Advance Design include Eurocode National Annex support and national Romanian standards such as CR0-2012 for combinations, CR1-1-3/CR1-1-4 for climatic actions, CR6-2013 for masonry and P100/2006 or P100-1/2013 for seismic analysis.
Italian workflows include NTC 2008 and NTC 2018 across several design areas, including combinations, climatic actions, concrete, steel, timber, masonry and seismic analysis. Use NTC standards when the project is located in Italy or where the project specification requires Italian national standards.
Canadian workflows include CBN 2010 / CBN 2015 for combinations and climatic actions, NBC 2010 / NBC 2015 / NBC 2020 for seismic workflows, CAN/CSA A23.3-14 for reinforced concrete, CAN/CSA S16-09 / S16-14 / S16-19 for steel and CSA O86-19 for timber. Use these standards for Canadian projects or projects requiring Canadian structural design rules.
US workflows include ASCE 7-10, ASCE 7-16 and ASCE 7-22 for selected load and climatic workflows, ACI 318-14 for reinforced concrete, ANSI/AISC 360-10 and ANSI/AISC 360-16 for steel, AISC 360-16 for composite design, NDS 2018 for timber, and ASCE/IBC seismic workflows. Use these standards when the project is located in the United States or where US design codes are specified.
Advance Design includes RPS 2011 for Moroccan seismic workflows and RPA99-2003 for Algerian seismic workflows. Use these standards where local seismic code compliance is required.
Selecting the right standard is not an isolated setup task. It affects the complete analysis and design workflow.
1. Model setup
The selected localization influences available material types, design assumptions and properties used by structural elements.
2. Load cases and combinations
Load combinations depend on the selected combination standard. If safety factors or design assumptions are changed after combinations have been generated, combinations may need to be regenerated.
3. Climatic load generation
Wind and snow load families are created according to the selected climatic standard. This affects wind regions, snow regions, exposure categories, roof parameters, pressure coefficients and other local code parameters.
4. Seismic load generation
Seismic load case families are created according to the selected seismic standard. This affects spectrum definitions, site class, importance category, behaviour factors and modal analysis parameters.
5. Material design checks
Concrete, steel, timber, masonry and composite elements are checked according to their selected standards and National Annexes. The standard affects resistance checks, deflection checks, stability checks, reinforcement assumptions and design reports.
6. Reporting
Calculation reports should reflect the selected standards, assumptions, load cases, combinations, results and design checks. This improves traceability and helps reviewers understand which regulatory framework was used.
Use this checklist before starting a project in FEA software Advance Design:
1. Confirm the project location. The location usually determines the applicable national rules.
2. Check the contract and authority requirements. The project brief may require a specific standard even if the project location suggests another.
3. Separate load standards from material standards. Wind, snow and seismic actions are not the same as concrete, steel, timber or masonry design.
4. Use the relevant National Annex where required. For Eurocode projects, the National Annex can change important parameters.
5. Set standards before generating combinations. Combination rules and safety factors should be configured before combinations are created.
6. Verify the selected standards before reporting. Use the Localization Settings dialog or status bar to confirm the project standards.
7. Document assumptions in the calculation report. Reports should make the selected standard, load cases and design checks clear.

GET STARTED FOR FREE
Advance Design is engineered to meet the specific needs of structural engineers, offering powerful FEM capabilities that streamline their workflow.