Description
Design of a parking in Advance Design.The ramps are supported cantilever beams supported by 10 underground columns. The structure is subject to weather variations and thus, a temperature gradient was introduced in the analysis. An elastic soil was defined to match the actual structure behavior. Project is complete and operational.
Design of a hospital with Advance Design. Building is a category IV seismical project, located in a zone 2 seismical area. Building is shaped as a curved half-pyramid, with seismical forces taken the few shear walls. An elastic soil was defined to match the actual structure behavior.
Design of an aeration tank with Advance Design. Project is a huge reinforced concrete structure for a total of 1230m3 of concrete and 173 tons of steel. An elastic soil was defined to match the actual structure behavior. Construction is over and the structure is currently being tested for waterproof.
User’s benefits: complete 3D FEM system with a lot of possibilities which allows structural engineers to handle complex subjects in the easiest way.