Designing Cross-Laminated Timber (CLT) Structures: Key Engineering Challenges and Solutions in Advance Design

23 September 2026Graitec Advance Design

GRAITEC Expert

Partager

blog-banner-designing-cross-laminated-timber-clt-structures.jpg

Advance Design 2027 models a cross-laminated timber panel as one planar element with a layered section, then runs Eurocode 5 checks layer by layer. Here is the workflow, and how it compares with hand calculations.

Cross-laminated timber (CLT) has moved from niche to mainstream, but analysing it is still awkward. A CLT panel is orthotropic, its layers behave differently depending on grain direction, and rolling shear in the cross layers can matter as much as bending. A common shortcut is to reduce the panel to a one-metre strip and check it by hand.

Advance Design 2027 offers another route. You model the panel as an ordinary planar (surface) element, describe its layers once, and the software assembles the stiffness, extracts stresses layer by layer and runs the Eurocode 5 checks. This article walks through the workflow in five steps, then compares two benchmark examples from the Advance Design CLT Design & Technical Manual with published hand calculations.

CLT in brief

CLT panels consist of at least three layers of boards glued together, with the grain of each layer rotated by 90° relative to its neighbours. That crosswise lamination gives dimensional stability and stiffness in both principal directions, so the same product works as a floor, wall or roof. Prefabrication is a large part of the appeal: CLT Polska, for example, quotes assembly times of 4–10 days for a shell, depending on project size.


Figure 1. A three-layer CLT panel: the grain of each layer is rotated 90° relative to the next.

In Eurocode-style design, only the layers parallel to the span are counted for bending resistance; the cross layers mainly transfer shear, which is why rolling shear is a frequent design check. Advance Design bases its checks on EN 1995-1-1:2004 (Eurocode 5) and the product standard EN 16351 and adds the torsional-shear and shear-interaction models from EN 1995-1-1:2025 where applicable.

One element, many layers

The key addition is a new finite element type, the Layered Shell. It extends the classical shell with a through-thickness layer structure: every layer has its own orthotropic timber material, thickness and angle (0° or 90° for CLT). The global stiffness is assembled from the individual layers, and internal forces and stresses are evaluated per layer, so the design checks work with lamella-level stresses instead of smeared section values.

Two section options deserve a deliberate decision. Ignore E90 sets the modulus of elasticity perpendicular to the grain to zero in the weak layers, which keeps the FEM model consistent with the Eurocode resistance model at the price of higher stresses and deflections. For out-of-plane shear, the Equivalent Energy Method is recommended for general floor modelling, while Stiffness Summation of Layers lets you calibrate the shear stiffness terms S44 and S55 with stiffness modifiers.

From blank model to code check in five steps

1. Choose the material

Advance Design ships an orthotropic CLT (C24) material in the EN 1995-1-1 (CLT) library. Its mechanical properties include E1 = 11 000 MPa along the grain and E2 = 370 MPa across it, and a dedicated design tab holds the characteristic strengths (fm,k = 24 MPa, fc,0,k = 21 MPa, fv,k = 3.5 MPa, rolling shear fr,k = 0.70 MPa) and γM = 1.25. The manual is explicit that these values must match the manufacturer’s declaration: the floor example below raises fr,k to 1.20 MPa, and the wall example defines a user material, CLT (C24)_USER_1, with E1 = 11 550 MPa and Gr = 65 MPa.


Figure 2. The built-in CLT (C24) material carries the strengths, γM and rolling shear values used by the Eurocode 5 checks.

2. Define the layered section

In the Layered Sections Manager you list the layers with material, thickness and angle. The Quick Generator does the routine work: pick the material, the number of layers and a layer thickness, and it creates the section with angles alternating between 0° and 90°. The library already holds more than 20 predefined sections with 3, 5 and 7 layers, which can be imported one by one or all at once, and sections in use can be exported to XML for reuse.


Figure 3. Layered Sections Manager: an 80 mm, three-layer section (20-40-20 mm) with alternating 0°/90° angles.


Figure 4. The Quick Generator builds a section from a material, a number of layers and a layer thickness.

Set the section type to CLT: only such sections are eligible for timber design, and they must have at least three layers, layer thicknesses of 6–60 mm and a total thickness of no more than 500 mm. The Stiffness Matrix button shows the resulting membrane, bending and shear matrices, so you can inspect the section before using it.

3. Model the panel like any other slab

Draw a planar element, set its type to Layered Shell and pick the layered section in the Material field. That is the whole modelling change; supports, loads and meshing work as they do for any surface element. The Timber Design block of the Properties window adds the timber data: whether the element is calculated, service class, system strength factor ksys, lamination width, the Plank-glued boards switch, deflection limits (winst, winst,Q, wfin, wnet,fin), reference length and plane, and, for walls, the buckling length.


Figure 5. The floor benchmark model: one planar element (CLT 160 L5s), two line supports, dead and live area loads.


Figure 6. The Timber Design block in the element properties: service class, ksys, deflection limits and buckling data.

4. Set the CLT design options

On the CLT Design tab of the timber design settings, choose which checks run: element strength (including torsional shear and superimposed shear stress) and element stability. Design can use smoothed forces, which average local mesh peaks, or non-smoothed forces, which keep the extremes and can be more conservative. The partial factor γM is taken from the material of each layer (Auto) or imposed for all of them.


Figure 7. The CLT Design tab: choose the checks, smoothed or non-smoothed forces, and the partial factor strategy.

5. Run the analysis and the design

After the FEM analysis, the timber design evaluates all load combinations and finds the governing forces for each element. The ULS package contains fourteen verifications: compression, compression with bending and tension with bending along both local axes, out-of-plane shear in both directions, in-plane shear, torsional shear, shear interaction, torsion with shear, superimposed shear and, for walls, buckling. The SLS package reports instantaneous, creep, final, net and variable-load deflections.

Reading the results

On screen, maps of the maximum work ratio (overall, and separately for deflections, strength and stability) show at a glance what governs, and each individual check reports its own work ratio. For FEM stress maps, the Results dialog lets you select a single layer, so any lamella can be inspected.


Figure 8. Design Results ribbon: display the maximum work ratio overall, or for deflections, resistance or stability.


Figure 9. The Results dialog includes a layer selector, so stress maps can be limited to a single lamella.

The Point Stresses tool plots a stress component through the thickness at a chosen mesh node and tabulates values at the top surface, the middle of each layer and the bottom surface. Three dedicated reports (CLT – Verification Report, Maximum Work Ratio – Resistance and Maximum Work Ratio – Deflection) document governing combinations and layer-level data.


Figure 10. Point Stresses: the stress through the thickness at a selected mesh node, with values for each layer.


Figure 11. The three dedicated CLT reports in the Report Generator.

Benchmark 1: a 5-layer floor

We reproduces an example from The CLT Handbook (2022): a single-span floor 40l-20w-40l-20w-40l (160 mm), L = 4.5 m, width 5 m, strength class C24, service class 1, gk = 1.1 kN/m² and qk = 2.0 kN/m², meshed at 0.3 m. Advance Design and the hand calculation agree closely.

 

Quantity Hand calculation Advance Design
MEd 11.35 kNm 11.32 kNm
VEd 10.09 kN 9.84 kN
σm,x,d 2.99 MPa 2.98 MPa
τxz,d 0.080 MPa 0.08 MPa
fr,d 0.768 MPa 0.77 MPa
winst 5.43 mm 5.39 mm
wcreep 2.38 mm 2.36 mm
wfin 7.81 mm 7.75 mm

 

Moments, stresses and deflections differ by less than 1%; the shear force differs by 2.5%. The work ratios are 19% for compression and bending, 10% for rolling shear, and 36%, 22% and 34% for instantaneous, final and net final deflection (winst = L/835 against a limit of L/300).


Figure 12. Bending moment map for combination 102: a peak of 11.32 kNm against 11.35 kNm by hand.


Figure 13. Instantaneous deflection: 5.39 mm at midspan.

Benchmark 2: a 3-layer wall

The second example comes from proHolz, Cross-Laminated Timber Structural Design, Volume 2 (2018), Example 6.1: a wall 30l-30w-30l (90 mm), L = 2.95 m, C24 with E = 11 550 MPa, E0,05 = 9625 MPa and Gr = 65 MPa, loaded with NEd = 57 kN/m and MEd = 1.31 kNm from wind, meshed at 0.2 m. Advance Design returns the same axial force and MEd = 1.30 kNm.

Quantity Hand calculation Advance Design
MEd 1.31 kNm 1.30 kNm
σc,0,d 0.95 MPa 0.95 MPa
σm,d 1.01 MPa 1.00 MPa
λrel 1.40 1.40
kc 0.46 0.46
fc,0,d 18.48 MPa 18.48 MPa
Work ratio (buckling) 16% 16%

The buckling check gives a work ratio of 16%. The manual recalculates the reference strengths with kmod = 1.10, whereas the book uses 1.0, so compare like with like when you benchmark against the source.


Figure 14. The wall benchmark: a 90 mm three-layer CLT wall, 5.00 m by 2.95 m, with a vertical line load and wind pressure.


Figure 15. Out-of-plane bending moment in the wall: a peak of 1.30 kNm against 1.31 kNm by hand.

Takeaways

The CLT-specific work sits in three places: the material, the layered section and the timber properties of the element. Everything else (geometry, supports, loads, mesh, load combinations) is the workflow you already use for slabs and walls. Two habits payoffs: compare the material data with the manufacturer’s declaration before you calculate and open the layer-level results before trusting a governing work ratio. Layered shells can also combine other materials in specific directions, but this article focuses on CLT.

Related content

What’s New in Advance Design 2027.1

10 November 2026Graitec Advance DesignGRAITEC Expert

Advance Design 2027.1 builds on the innovations introduced in Advance Design 2027, delivering enhanced AI-powered capabilities, expanded automation possibilities, and…

A Quick-Start Guide to the Advance Design API

20 October 2026AI, FEM software, Graitec Advance DesignGRAITEC Expert

Discover how the Advance Design API enables structural analysis automation, software integration, and AI-assisted model creation with Python and other…

Retaining Wall Design Made Simple with Advance Design

12 October 2026FEM software, Graitec Advance DesignGRAITEC Expert

Discover how Advance Design simplifies Retaining Wall Design with automated calculations, Eurocode compliance, reinforcement detailing and drawing generation.